pentair pool pump error codeark breeding settings spreadsheet
The thermal regulator must be in good functioning order and in the correct position. Pentair Heater Error Codes [Reasons + Solutions] 1. Remove cord connector from top of pump and dry out with cloth or hair dryer. They mean the same. And does anyone have a possible idea as to what is happeneing? In some cases, you may need to replace your current pump with a new one entirely. This is caused by insufficient water flow through the heater. If purchased online will only receive a sixty-day limited warranty. The main reason behind Pentair Mastertemp won't turn on is the automatic gas shut-off. I got a new one from Pentair. I like the fact that it can down convert the voltage and be used at 120V as well as at 230V. The pump ran fine yesterday. How to Fix an Err 0002 on a Pentair SuperFlo Vs Pump. priming mode and then start up. fix the error codes E01 and E126 with your Pentair pool heater, Pentair heaters service light may turn on, how to fix the Pentair heater error code R13, comprehensive guide on how to deal with Pentair heater error code R14, How To Fix Pentair Pool Heater Error Codes E01 [Solved], Suburban Water Heater Wont Stay Lit [11 Easy Fixes], Richmond Tankless Water Heater Troubleshooting [A Complete Guide], Richmond Electric Water Heater Troubleshooting [A Complete Guide], Richmond Gas Water Heater Troubleshooting [A Complete Guide], Richmond Water Heater Blinking Light Codes [Why+ How To Fix], Richmond Water Heater Gas Valve Problems [Why + How To Fix]. This is totally a manufacturing problem on pentair's end. ERR AFS Error Code 4. If adequate airflow via the blower is restored within 60 seconds after the problem message shows, the heater will resume normal performance. It could be a bad drive but that is not common. 21 -Communication link between HMI and motor control has been lost. Gently turn it back in forth until the Save my name, email, and website in this browser for the next time I comment. New Pentair pump giving error codes 0002 and 000F Hi, I recently replaced my pool motor and had my new VS SuperFlo working for about 1-2 weeks. The second method is to use a Allen Wrench and insert it into the back of the pump. Check the fuel supply, the heat regulator, and any orifice blockages again. I then did each line separately and found out one wasn't connected to the double pull GFI breaker correctly. . turn it off. Now, every morning when is scheduled to turn on, it shoots out error codes 0002 and 000F. Ecommerce (EC) products: Products purchased from an Authorized Pentair . choice for a Variable Speed Pump. If they do not clear after multiple restart attempts, the drive should undergo a hard power cycle. Needed 7/8" wrench. What would be the cause of that? is connected at the skimmer you may want to try the after-market Hole in One Basket Your information will *never* be shared or sold to a 3rd party. It does this at all speeds not just one on setting. The screen will display an error code as Err and then display a number. Pentair heaters sometimes display codes R13 and R14. Improper voltage or supply voltage. ERR HLS Error Code 3. Replacement drive did the same thing so i started doing some basic troubleshooting and i think i figured out the cause. 0F Absolute AC Under-Voltage Detected: This indicates that the supply voltage has dropped below the operating range of 99v. The control board may also be the culprit and checking it with a multimeter should confirm it. See page 14 Pump Disassembly for instructions for disassembling the pump. Use the following troubleshooting guide to repair common heat pump issues and get technical support. Nothing made it work so I bought a new one. At this point you may want to call out a pool service professional to trouble shoot the pump. When the pump is running it seems to run for 20 - 30 minutes then it cuts off for 15 - 20 seconds then comes back on. Hello , This is an inactive thread. I originally posted it only so the folks at pentair could see it and totally forgot about it. You are using an out of date browser. JavaScript is disabled. Using its control panel, you can easily set and reset the 4 selectable preset speeds or set the pump speed to run at a certain speed. Spin it I tested that ground circuit from my breaker box and was getting very odd readings. To fix the error codes E01 and E126 with your Pentair pool heater, very first, inspect whether the thermistor is working. It is very reliable and will give you years of Hi, I recently replaced my pool motor and had my new VS SuperFlo working for about 1-2 weeks. The factory settings will be in assigned. Pentair superflow vs Faults and Alarms If an alarm is triggered the drive's LCD screen will display the fault code text and the pump will stop. It may take a bit of effort. When the gas flow shuts off due to the faulty pressure switch or low flow rate, then your heater will face this issue. If it is connected at the skimmer you may want to try the after-market Hole in One Basket for the skimmer. Pentair X-Flow Xpert Web App; Aurora . When you dont use a sun cover, the heat that your heat pump puts into the pool is lost into the air. The Hole in One Basket: Connect a Cleaner at the Effect 10 RPM increments by pressing and quickly releasing the down/up to decrease or release the pump speed. one or two resets. The Same as E05, clogged exhaust or air vents, a sooted exchanger, inadequate water flow, or a defective stack flue sensor are all possible reasons for this mistake. to remove the pump lid and pump basket, then I spin the impeller with a Other reasons why the heater is not turning on include: Faulty igniter The defective ignition control module Bad control fuse Run the filter pump for a few minutes after turning on the heater for the first time or after a long period of time off to clear all air from the system. In this section, we will look at what each error code means and what are the simple solutions for these errors. Troubleshoot the high-pressure issue causing the error. But more than likely when you service professional to trouble shoot the pump. If the blockage was removed the screen There is either a white or yellow wire connected directly to the back of the board. Press J to jump to the feed. 001a Error code on Pentair Superflo VS pump. Pool Heat Pump Repair | Pool Heater Repair, Energy Saving Tips For Your Swimming Pool, Measure water temperature with a thermometer to rule out a faulty temperature sensor, Hire professional pool heat pump repair tech to inspect control board, thermistor, andunit, See HIGH WATER TEMP troubleshooting steps, Check that pool pump is sending water to heater, Ensure that pool pump is receiving enough water, Check that your pool systems multiport valves are on the correct settings, Have pool heater repair tech check for bad pressure switch (or check it yourself), Seek pool heater repair tech to troubleshoot the water thermistor, Seek pool heater repair tech to troubleshoot the defrost thermistor, Check that transformer supply voltage is within 208 260 volts, Check that transformer outputis between 24 28 volts, Replace transformer is voltage is below those ranges, Check that heat pump supply voltage is between 208 -260 volts, Ensure that pool pump is sending water to your pool heater, Check for any blockage in baskets and filters that are affecting water flow, Have pool heater tech inspect higher-pressure switch, The unit may have a refrigerant leak. You should Pentair IntelliFlo 2 VST. You should be able to press the start/stop button to start up the pump. It Hi, I have an error code on my Pentair variable speed pump. The problem can be a malfunctioning blower fan or blockage of the fan air. I can make it work if I take an Allen wrench and manually spin the impeller for a few rotations. Seek professional heat pump repair, Outside temperatures are too low to operate, Have pool heater tech check if the switch needs to be replaced, Check for additional error codes that are listed in this post. Freeze protection is provided by selecting YES at the ON WITH FREEZE 21 Communication Link between the HMI and Motor control has been lost: Check the jacketed wire on the backside of the keypad inside the drive top cover. You can turn the impeller by using a 1/4 allen wrench at the back in the fan. Clogged exhaust or air vents, a sooted exchanger, inadequate water flow, or a defective stack flue sensor are all possible reasons for this mistake. Maybe i will take the drive apart and add some pictures to the end of the video if i get motivated. Error Code R14: Revision Mode 5. The pump is brand new and never used. The Pentair SuperFlo Variable Speed pump is a great I got that a few times the other day while backwashing but the pump Would kick on a second or two later. The Pentair heater error codes displayed in your heater display tell you that you need to address specific issues with your heater. Be sure to contact us through our website for our variety of services.. It will then begin to go into the priming mode and then start up. Possible causes could be loose or damaged wiring, poor wiring connections, wrong wire type, wrong wire gauge, or issues with the relay or breaker associated with the pump. Pentair Minimax NT STD ERR message Postby Guru Thu 18 Feb, 2010 14:40 9 times out of 10 the "ERR" code is caused by a bad thermistor (temp sensor). Error Code AD0: Bad Keypad 6. Read our troubleshooting guide to figure out how to fix a faulty Pentair blower. If the blockage was removed the screen will no longer show the Err 0002 code. external slip) Spin it completely around several times to make sure the blockage is cleared. Followed instructions on page 14 of manual. I set up a gopro for hours and finally caught it giving and error 0021.Pentair was an absolute disaster to deal with but i was finally able to get them to send me a new drive. Is that an overcurrent fault code? When I give it power I immediately get the following error: You must log in or register to reply here. It is probably a built-in failsafe so that the pump doesnt overheat and become damaged. E05 Error Code 9. The screen will display an error code as Err and then display a number. 27K views 1 year ago Videos on Heaters If your heater is displaying an eo5 or eo6 error code there is a simple fix. Error Code R13: Startup Mode 4. we cater to all your pool and spa needs with the utmost customer assistance. The ERR IGN code indicates ignition failure. A malfunctioning ignitor, a busted control module, a clogged or damaged flame sensor, a bad thermal regulator, or defective AGS or AFS are the likely reasons. See "HP Indicator" LPIndicator ISSUE The refrigerant system's low-pressure switch is showing as open. : https://youtu.be/huAt9BXLu9ISuperFlo VS Playlist: https://www.youtube.com/playlist?list=PLsvsTjbpoT-dsZaZkJevqaCgR7Tfl2XzPVisit my Website: http://www.swimmingpoollearning.com/eBook: https://www.swimmingpoollearning.com/swimming-pool-care-ebookYouTube Video Index: http://poolmandave.blogspot.com/2014/03/swimming-pool-tips-reviews-how-to-video.html A list of all of my videos.Follow Me:Google +: https://plus.google.com/+MrDgvb1/postsBlogger: http://poolmandave.blogspot.com/ Facebook: https://www.facebook.com/pages/Youtube-Mrdgvb1/381257741926763?ref=hl Twitter: https://twitter.com/Mrdgvb1Join me on Patreon: https://www.patreon.com/poolguycoachingPodcast: http://www.buzzsprout.com/110832Podcast Website: https://www.thepoolguypodcastshow.com/Coaching Site: https://poolguycoaching.com/Shop INYOPools: www.inyopools.com?utm_source=youtube\u0026utm_medium=swimming-pool-tips The cooling effectiveness of either a heat pump or an air conditioner can be improved by shading the exterior unit. A malfunctioning thermistor, poor or damaged wiring, a bad control board, or a failed temperature sensor are all possible causes. Anti-freezing: When active, the motor will run at 1000 rpm for 60 minutes. I also use the screwdriver to scrape away any debris that may be jammed in there. So, if you have an older pool Make sure that the pump is on by ensuring that the LED power is on. ERR AGS Error Code 6. start/stop button to start up the pump. When the heater doesnt have sufficient air flowing through, the airflow switch trips. I have an error code on my Pentair variable speed pump. Energy & Cost Savings Slow and steady wins the race. The Pentair SuperFlo Variable Speed pump is a great choice for a Variable Speed Pump. Impeller is stuck or jammed with debris. How long does a Pentair pool heater take to heat a pool? E06 Error Code 2 More Confused Error Codes Of Pentair Heater 1. insert it into the back of the pump. E01/E126 Error Code 8. I put my voltage meter on the pump's load 1 and load two and it only read 118V. Error Code E05: Stack Flue Sensor Is Open 2. It happens when the water temperature is above 135F while passing through the heat exchanger. Replace if it is bad. This is especially useful in the afternoon when your houses cooling needs are highest and its cooling efficiency is lowest. When the motor is stopped it is not drawing much current. When I give it power I immediately get the following error: F90052 ALARM! It says "Err" and then "0002" and won't turn on. Remove side access panel, two screws. 02 - Absolute Phase current limit exceeded. You should be able to press the start/stop button to start up the pump. Doing this may free the blockage. Its like not insulating your houses loft if you dont utilize a sun cover. I do have pine needles that make it through the basket occasionally, so wondering if those are getting caught. It is probably a built-in Power off the unit and restart. Press question mark to learn the rest of the keyboard shortcuts. pump or a poor connection. I figured it out. Any new postings here are unlikely to be seen or responded to by other members. getting clogged and the pump is unable to prime. Who Makes the Best Pool Equipment -Pentair, Hayward, Jandy or Off Brands? 12 Pentair Heater Error Codes, Their Meanings & Solutions 1. I was imagining the WORST like voltage drop from the house which would involve running another but thicker wire 500 feet! You need to test each of the components to see if they are the culprit. So, if you have an older pool on a single 110V breaker the SuperFlo VS pump is pretty much the only Variable Speed Pump that you can install. All rights reserved. pump was working now just blinks yellow wont start any suggestions ?? Remove any obstructions. The method I always use is Decoding the errors on your pump 21 - Communication link between HMI and motor control has been lost Press your desired speed button (from 1 to 4) for about 3 seconds to choose the preset pump speed to reset the speed. This is because, after 60 seconds of mistake, the heater will enter lockout mode. Disclaimer, if you chose to do this it is at your own risk. Variable speed pumps move water more efficiently at lower speeds, saving money and energy. But if the water temperature is cool enough but the error message is still there, it means that there is something wrong with the high-limit switch. Read our article on Pentair ignition failure to learn more. Insufficient water flow is usually caused by a dirty filter. You will get much more visibility by. You must log in or register to reply here. Go for the same solution as we have suggested for the E05 error code. It simply means that your heaters system is being examined for possible problems. completely around several times to make sure the blockage is cleared. Learn more Shop Now Pentair - EC-011059 - IntelliFlo i1 Variable Speed Pool Pump - Limited Warranty $1,859.00 Also make sure both the skimmer and pump basket do not have rips or tears which could allow debris to get through and into the pump impeller. Once the impeller spins freely the blockage has been Error Code ERR HLS: Hi Temperature Switch Is Open Views: 44 Report Jimrahbe Mod Squad TFP Expert LifeTime Supporter Jul 7, 2014 28,282 Bedford, TX Benefits of a Pentair Variable Speed Pool Pump Higher Performance Consistent flow control for the highest energy saving and ultimate system performance. But more than likely when you clear the impeller jam the pump will start up and run like normal. If the error has not cleared then proper troubleshooting will be required. If you have a suction side cleaner Please consider. The most common one is the Err 0002 and it is usually caused by the impeller getting clogged and the pump is unable to prime. Doing this may free the blockage. Maybe thats why you initially mistook it for an error code. All Right Reserved by HeaterFixLab. Make sure that your variable pump is on this means ensuring that the green power LED is turned on. will prevent the pump from running until you clear the blockage. The Number One Source for All of Your Pool Care Needs. The ERR HLS code means that your heaters high-limit switch is stuck open. There are two ways to clear the blockage. If the above does not work you will need to have the pump and connections tested with a multimeter to see where the short is. I went and checked the pumped and the display screen said "Err 0021". I tried hard resetting and turning off power for multiple minutes. RESOLUTION Deactivate then reactivate power to the heat pumpto clear error. I apologize to anyone who found this seemingly useless video with no description. like this try this first before you replace the p. AboutPressCopyrightContact. ERR- ERROR Code ERR indicates a "hard lockout" error which means you will need to reset the power of the heater through the switch on the bottom of the electrical junction box once the errors are fixed. So, if you. We are a registered 501(c)3 non-profit that is funded by user donations. Pentair vs superflow model350879.A error code A1. These codes arent an indication of an error but users get confused as to what they mean. Please disassemble the pump and investigate to see if there is a problem with the impeller or mechanical seal. We are a registered 501(c)3 non-profit that is funded by user donations. I only saw it that day, didnt do anything about it and havent had a problem since. COPYRIGHT 2023. Pentair IntelliFlo3 VSF 3.0HP with I/O Board, Youtech - Home Services Digital Marketing Agency. Call the installer and have them check it out or have them get a warranty tech from Pentair to fix it. I checked voltage at the pump and I am getting 230V consistently. You can press the start button to assign the selected speed if necessary.